Base Q

analog gas meter

analog gas meter

for sizes G1,6; G2,5; G4; G6

1250

UAH without VAT
UAH without VAT

current retail price

current retail price

актуальна роздрібна ціна

актуальна роздрібна ціна

Advantages

Advantages

measurement accuracy

точність вимірювань

we guarantee a class of accuracy 1.5
in the stated range of flow rates

durability

довговічність

all nodes are designed for reliable
operation over 20 years

modem connector

розʼєм для модему

the possibility of integration with
remote systems

thermal stability

thermal stability

stable operation in the specified
temperature range

thoughtful design

thoughtful design

that does not require
maintenance

temperature correction

temperature correction

the measured volume is displayed adjusted to standard conditions

Technical Specifications

Technical Specifications

Parameter name / Meter size

Parameter name / Meter size

Nominal consumption, Qnom, m³/h

Maximum consumption, Qmax, m³/h

Minimum consumption, Qmin, m³/h

  • standard version

  • custom version

Transitional flow rate, Qt, m³/h

Transitional flow rate, Qt,
m³/h

G1,6

G1,6

1,6

2,5


0,25

G2,5

G2,5

2,5

4


0,025

0,016




0,025


0,016

0,4

G4

G4

4

6


0,04

0,016




0,04


0,016

0,6

G6

G6

6

10


0,06

0,025



0,06


0,025

1

Nominal displacement volume, dm³

Nominal connection diameter, mm/thread of connecting

fittings (ISO 228-1) (depending on the order)

Mass, kg, max

The distance between connecting fittings, mm

Overall dimensions LxWxH, mm, max

1,2

20/G3/4; 25/G1; 32/G1 1/4

20/G3/4;
25/G1;
32/G1 1/4

1,9

110/130

205x168x220

2

32/G1 1/4

32/G1
1/4

3,8

250

338x174x248

338x174
x248

338x
174x
248

Class accuracy

Class of external mechanical conditions

The limits of permissible relative error in the ranges of flow rate

of volumetric flow at a temperature of (20±2) °C:

  • Upon release from production and after repairs:

in the range of flows from Qt ≤ Q ≤ Qmax
in the range of flows from Qmin ≤ Q < Qt

  • During operation:

in the range of flows from Qt ≤ Q ≤ Qmax

in the range of flows from Qmin ≤ Q < Qt

Sensitivity threshold, max, m³/h

Maximum excess working pressure

The average pressure loss value for flow Qmax, Pa,
not more than:


  • When released from production and after repair

  • During operation

Capacity of the measuring device, m³

Operating temperature range, °C

Standard gas temperature, tb, °C *

The specified average temp., tsp, °C *

The price of the minimum division of the measuring device,

dm³

Service life

1,5

M1

M1





± 1.5 %

± 3 %

± 3 %

from minus 6% to 3%







± 1.5 %

± 3 %

± 3 %

from minus 6% to 3%
















± 1.5 %



± 3 %




± 3 %



from minus 6% to 3%

0,003

50 kPa (0,5 bar)




200

220





200


220







200





220

99999,999

from minus 25 to 55

20

20

0,2

20 years

* - for the model with a built-in temperature conversion device

* - for the model with a built-in
temperature conversion device